Ethernet Extender with Management system
ECP-2808RM / ECP-2816RM / EUP-2808RM / EUP-2816RM
Ethernet Extender (Unmanaged)
ECP-2701 / ECP-2704T / ECP-2704R / ECP-2601 / ECP-9501 / ECP-8401 / ECP-8301 / ECP-9504R / ECP-9508R / ECP-9516R
Our 4/8/16-channel receivers are designed to distribute the maximum transmission rate per 4 ports. If all the devices are connected to 4 channels, the maximum transmission rate will be reduced to about 20% of the transmission rate in 1-to-1 connection.
(For example, the maximum transmission rate of ECP-9501 is 95Mbps in case of 1: 1, but it would be about 20Mbps with ECP-9504R, ECP-9508R, and ECP-9516R.)
Mostly, the coaxial cable is RG-59 / 5C-HFBT (75Ω), the twisted pair cable is Cat.5E UTP.
. Check that the network cable is in good condition and has been assembled correctly.
. Confirm if the camera is IEEE802.3af/at PoE Compliant.
. Please check that the Ethernet length does not exceed transmission distance limitation of 100 meters.
. Check the PoE output Switch on the Transmitter is set to ON.
. Due to power drops on the cable, may need extra 56V power supply on the transmitter.
. Check that the cable length does not exceed transmission distance limitation of 100 meters.
. Power the transmitter with separate power supply to check it turns on.
. Check that the cable length does not exceed transmission distance limitation
(e.g 500 meters)
. Check the cable condition and ensure all BNC / RJ-45 connection are secure.
. Check if there’s any kind of signal booster, noise filter, repeaters, other amplifiers
for the signal on cable, if yes, please remove them before installation of the devices.
(e.g 500 meters). Check the cable condition and ensure all BNC / RJ-45 connection are secure.
. Check if there’s any kind of signal booster, noise filter, repeaters,
other amplifiers for the signal on cable, if yes, please remove them before installation
of the devices.
. Check the Coax / UTP cable if it is shorted.
. Check the Coax / UTP cable if it is connected properly.
. Check UTP cable order if it is correct (Cable order should be EIA/TIA-568B Type)
. Check if the password of the Local Node (Receiver)
and Remote Node (Transmitter) is matched.
. If the password of local node(Receiver) and remote node(Transmitter) is not matched
or unknown password is entered, please join the both devices again
. Check the Coax / UTP cable if it is shorted.
. Check if the power supply system is properly connected.
. Check the system input voltage from the power source.
. If the problem persists even after you have taken the above actions,
check power cable and replace it if necessary.
. Check if coax / UTP cable is connected properly.
. Check if B-Linx / T-Linx Port LED is ON.
. Check if the network port is properly connected and the network setting is set correctly.
. Check the system for the input voltage from the power source.
check the other network device settings (e.g. IP camera, NVR, etc)